Find equipment
Get your quote
What would you like to test?
Primary equipment
Secondary equipment
What would you like to test?
Current Transformers (CTs)
Voltage Transformers (VTs)
Power Transformers (PTs)
Power Lines or HV Cables
Grounding Systems
Rotating Machines
Switchgear and Circuit Breakers

What would you like to perform?
Common Electrical Tests incl. Bushing Tests
Dissipation Factor / Power Factor Measurements

There is one option
CT Analyzer

Would you like to perform Impedance, K-Factor & Mutual Coupling Measurements?
Yes
No

Unfortunately, there is no other equipment available at the moment.

What would you like to perform?
Contact Timing Tests
Voltage Withstand test on MV Swichgear
Voltage Withstand test on GIS (with Siemens Power VT)
Contact Resistance Measurements (Micro-Ohms)

There are two options
Doble TDR900

There are two options
Elcon Switch Analyzer SA10

What would you like to test?
MV Protection / Distribution Systems
HV Protection / Transmission Systems
Substation Automation systems
Calibrate measurement devices
Optical connections

Would you like to test old electromechanical relays?
Yes
No

There are two options
Cmc 15
Cmc 256

What would you like to test?
Sampled values (IEC61850-9-2)
Old electromechanical relays

There are two options
Omicron CMC 256
Omicron CMC 356

Would you like to test Old electromechanical relays?
Yes
No

There are two options
Omicron CMC 256
Omicron CMC 356

There are two options
Omicron CMC 256
Omicron CMC 356

What would you like to test?
Optical connections

Opftical Fibre Test Set
More to Come

The CMC 356 is the universal solution for testing all generations and types of protection relays. Its powerful six current sources (three-phase mode: up to 64 A / 860 VA per channel) with a great dynamic range, make the unit capable of testing even high-burden electromechanical relays with very high power demands. Commissioning engineers will particularly appreciate its ability to perform wiring and plausibility checks of current transformers, by using primary injection of high currents from the test set.

The CMC 356 is the first choice for applications requiring the highest versatility, amplitude and power. Commissioning engineers will particularly appreciate its ability to perform wiring and plausibility checks of current transformers, by using primary injection of high currents from the test set.

6 Phase Current + 4 Phase Voltage Test Set and Commissioning Tool

  • 01

    6 x 32 A / 430 VA

  • 02

    3 x 64 A / 860 VA

  • 03

    1 x 128 A / 1000 VA

  • 04

    4 x 300 V