Fluke 1625
Find equipment
Get your quote
What would you like to test?
Primary equipment
Secondary equipment
What would you like to test?
Current Transformers (CTs)
Voltage Transformers (VTs)
Power Transformers (PTs)
Power Lines or HV Cables
Grounding Systems
Rotating Machines
Switchgear and Circuit Breakers
What would you like to perform?
Common Electrical Tests incl. Bushing Tests
Dissipation Factor / Power Factor Measurements
Unfortunately, there is no other equipment available at the moment.
What would you like to perform?
Contact Timing Tests
Voltage Withstand test on MV Swichgear
Voltage Withstand test on GIS (with Siemens Power VT)
Contact Resistance Measurements (Micro-Ohms)
What would you like to test?
MV Protection / Distribution Systems
HV Protection / Transmission Systems
Substation Automation systems
Calibrate measurement devices
Optical connections
What would you like to test?
Sampled values (IEC61850-9-2)
Old electromechanical relays
What would you like to test?
Optical connections
Opftical Fibre Test Set
More to Come
Fluke 1625-2 Earth Ground Tester offers fast, accurate earth ground testing using all four test methods.
The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.
Keep your options open If a bonded earth ground system does not exist for the building or structure under test, and there is only one path to ground, you can use the 1625-2 to perform the fall-of-potential test method with stakes.
The 1625-2 offers other advanced features including:
Automatic Frequency Control to identify existing interference and choose a measurement frequency to minimize its effect, thus providing a more accurate earth ground value. R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see.
The 1625-2 is also very easy to use. World class accessories speed set up and test time. And the tester tells you which stakes or clamps to connect for each test. The large rotary switch and buttons are easy to operate even with a gloved hand. And you can store up to 1500 records and access them easily via the USB port.
Other useful capabilities:
- 01
Provides R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
- 02
Includes USB port for data storage and transfer
- 03
Features IP56 rating for outdoor use
- 04
Offers adjustable limits for quicker testing
- 05
Comes with a rugged carrying case